상세 컨텐츠

본문 제목

Zoll Lifevest 4000 Manual

카테고리 없음

by ciatrathaman1975 2020. 2. 29. 03:18

본문

  1. Zoll Lifevest 4000 Manual
  2. Zoll Lifevest 4000 Manual Download
  3. Zoll Lifevest 4000 Manual 2017

.E Series Service Manual ® 9650-1450-01 Rev. D January 2014.Service Manual (REF 9650-1450-01 Rev. D) is January, 2014. If more than 3 years have elapsed since this date, contact ZOLL Medical Corporation to determine if additional product information updates are available. Copyright © 2014 by ZOLL Medical Corporation. All rights reserved.

AutoPulse, Base Power Charger, CPR-D-padz, E Series, Pedi-padz, Protocol Assist Code Markers, Real CPR Help, Rectilinear Biphasic, RescueNet, See-Thru CPR, SmartAlarms, Stat-padz, SurePower, and ZOLL, are trademarks or registered trademarks of ZOLL Medical Corporation in the United States and/or other countries.Overview.1-1 Before You Begin the Maintenance Tests. 1-2 Equipment that You Need to Perform the E Series Maintenance Tests. 1-3 Equipment You Need for the E Series Options Maintenance Tests.1-3 Physical Inspection of the Unit.1-5 Front Panel Button Test.Chapter 2 Troubleshooting Overview.2-1 Troubleshooting. 2-2 ZOLL E Series Error Messages.2-5 Chapter 3 Replacement Parts Replacement Parts.3-2 Parts Diagrams.3-7 Chapter 4 Functional Description Main System Board.4-2 High Voltage Module.4-7 AC/DC Charger Module.4-10 System Interconnect Module.4-11.High Voltage Assembly Removal. 5-23 Battery Interconnect Board Removal.5-24 A/C Charger Assembly Removal. 5-26 Access Detect Cable Removal.5-27 Capacitor Removal.5-28 Connector Panel Removal.

4000

Zoll Lifevest 4000 Manual

5-29 Communication Board & PCMCIA Module Removal. 5-31 Recorder Removal.9650-1450-01 Rev.D.Safety and effectiveness data submitted by ZOLL Medical Corporation to the Food and Drug Administration (FDA) under section 510(K) of the Medical Device Act to obtain approval to market is based upon the use of ZOLL accessories such as disposable electrodes, patient cables and batteries. The use of external pacing/defibrillation electrodes and adapter units from sources other than ZOLL is not recommended.Do not discharge a battery pack except in a ZOLL SurePower™ Charger Station or compatible ZOLL Battery Charging/Testing unit.

Zoll Lifevest 4000 Manual Download

Do not use the E Series in the presence of flammable agents (such as gasoline), oxygen-rich atmospheres, or flammable anesthetics. Using the unit near the site of a gasoline spill may cause an explosion.Purchase Order for a unit with an expired warranty. If the unit needs to be sent to ZOLL Medical Corporation, obtain a Service Request number from the Technical Service representative.

Return the unit in its original container to: 9650-1450-01 Rev. D.Technical Service for International Customers International customers should return the unit in its original container to the nearest authorized ZOLL Medical Corporation Service Center.

Zoll Lifevest 4000 Manual 2017

To locate an authorized service center, contact the International Sales Department at ZOLL Medical. See back cover of this manual.The E Series has two checkout procedures: the operator’s shift checklist and the extensive six-month maintenance tests checkout procedures. Because the E Series units must be maintained ready for immediate use, it is important for users to conduct the Operator’s Shift Checklist procedure at the beginning of every shift.Assemble the tools or specialized testing equipment listed in the “Equipment You Need to Perform the Maintenance Tests” section shown below. Keep an extra fully charged ZOLL E Series compatible battery available. Schedule an hour to conduct the entire maintenance test.Be sure to follow the manufacturer’s recommendations for conducting the maintenance tests.